Davut, K.; Zaefferer, S.: Improving the Reliability of EBSD-based Texture Analysis by a New Large Area Mapping Technique. Materials Science Forum 702-703, pp. 566 - 569 (2012)
Davut, K.; Zaefferer, S.: The effect of size and shape of austenite grains on the mechanical properties of a low-alloyed TRIP steel. Steel Research International 83 (6), pp. 584 - 589 (2012)
Davut, K.; Gür, C. H.: Monitoring the Microstructural Evolution in Spheroidised Steel by Magnetic Barkhausen Noise Measurement. Journal of Nondestructive Evaluation 29, pp. 241 - 247 (2010)
Davut, K.; Zaefferer, S.: Statistical Reliability of Phase Fraction Determination Based on Electron Backscatter Diffraction (EBSD) Investigations on the Example of an Al-TRIP Steel. Metallurgical and Materials Transactions A 41 (9), pp. 2187 - 2196 (2010)
Davut, K.; Zaefferer, S.: The effect of texture on the stability of retained austenite in Al-alloyed TRIP steels of Al-alloyed TRIP Steels. MRS 2010 Fall Meeting, Boston, MA, USA, 2011. (2011)
Davut, K.; Zaefferer, S.: Improving the Reliability of EBSD-based Texture Analysis by a New Large Area Mapping Technique. International Conference on the Textures of Materials, ICOTOM 16, Mumbai, India (2011)
Davut, K.; Zaefferer, S.: Factors influencing the strain-induced transformation of residual austenite in a low-alloyed TRIP steel. Euromat 2011 Conference, Montpellier, France (2011)
Davut, K.; Zaefferer, S.: A new large-area mapping technique to improve the statistical reliability of EBSD datasets. Royal Microscopy Society (RMS) EBSD 2011 Meeting, Düsseldorf, Germany (2011)
Davut, K.; Zaefferer, S.: The effect of texture on the stability of retained austenite in Al-alloyed TRIP steels of Al-alloyed TRIP Steels. MRS 2010 Fall Meeting, Boston, MA, USA (2010)
Davut, K.; Zaefferer, S.: Statistical Reliability of EBSD Data Sets for the Characterization of Al-alloyed TRIP Steels. 15th International Metallurgy and Materials Congress, Istanbul, Turkey (2010)
Davut, K.; Zaefferer, S.: Statistical Reliability of Phase Fraction and Texture Determination Based on EBSD Investigations on the Example of an Al-TRIP steel. Royal Microscopy Society (RMS) EBSD 2010 Meeting, Derby, UK (2010)
Davut, K.; Zaefferer, S.: Phase fraction and texture quantification of Al-TRIP steel from EBSD data. 3rd Int. Conf. On Texture and Anisotropy of Polycrystals (ITAP-3), Göttingen, Germany (2009)
Davut, K.; Gür, C. H.: Monitoring the Microstructural Evolution in Spheroidised Steel by Magnetic Barkhausen Noise Measurement. 7th Int. Conf. on Barkhausen Noise & Micromagnetic Testing, Aachen, Germany (2009)
Davut, K.; Zaefferer, S.: Effect of step size and scanned area on phase fraction and texture quantification from EBSD data. DGM-DVM, EBSD-Workshop 2009, Mikrostrukturuntersuchungen im REM, Chemnitz, Germany (2009)
Max Planck scientists design a process that merges metal extraction, alloying and processing into one single, eco-friendly step. Their results are now published in the journal Nature.
Scientists of the Max-Planck-Institut für Eisenforschung pioneer new machine learning model for corrosion-resistant alloy design. Their results are now published in the journal Science Advances
Hydrogen in aluminium can cause embrittlement and critical failure. However, the behaviour of hydrogen in aluminium was not yet understood. Scientists at the Max-Planck-Institut für Eisenforschung were able to locate hydrogen inside aluminium’s microstructure and designed strategies to trap the hydrogen atoms inside the microstructure. This can…
Electron microscopes offer unique capabilities to probe materials with extremely high spatial resolution. Recent advancements in in situ platforms and electron detectors have opened novel pathways to explore local properties and the dynamic behaviour of materials.
Oxidation and corrosion of noble metals is a fundamental problem of crucial importance in the advancement of the long-term renewable energy concept strategy. In our group we use state-of-the-art electrochemical scanning flow cell (SFC) coupled with inductively coupled plasma mass spectrometer (ICP-MS) setup to address the problem.